<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-11 07-52-12
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 62 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 15 kHz 17167 10,0600
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,0 dBr 3,61 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 15 kHz MIN: 9 kHz % above 76 kHz: 10,0600 Acquired: 2025/03/11 7.51.09 Total samples: 17167 Equivalent time: 0:14:18 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,3 dBr MIN: 1,0 dBr AVE: 3,61 dBr % above 12,2 dBr: 0,0 Last value: 1,4 dBr (2025/03/11 7.51.09) 07.38 07.40 07.42 07.44 07.46 07.48 07.50 0 2 4 6 Pm [dBr]